Silicon Bands, Tires & Sponges |
|
| |
- Silicon Bands ? Style available - 240 (2.5mm), 41 (3.5mm), 42 (4mm) & 43 (5mm)
- Silicon Tires ? Style available - 276, 277, 279, 280, 281 & 287
- Silicon Sponges ? Diameter available - 3.0mm, 4.0mm, 5.0mm & 6.0mm
|
|
| |
Landers Vitrectomy Lens Set |
|
| |
This vitrectomy lens system comprises of a set of contact lenses (with concave contact surface) and a ring to hold the contact lenses in position. The main advantage of this system is that it minimizes the dependence of a well-trained assistant. The set comprises of the following lenses:
- MILR Silicon ring
- MILR1 Stainless steel ring with two notches
- MILR2 Stainless steel ring with two struts
- MIL1 Machemer flat lens
- MIL2 Tolenteno prism lens 20
- MIL3 Tolenteno prism lens 30
- MIL4 Machemer magnifying lens
- MIL5 Paymen wide field lens
- MIL6 Landers biconcave-90 D lens
- MIL7 Woldoff prismatic biconcave lens
|
 |
| |
Irrigating Vitrectomy Lens Set |
|
| |
Landers Biconcave Irrigating Vitrectomy lens (-90D)
It is designed to view the fundus in air-filled phakic and pseudophakic eyes. This lens has a refractive power of -90D, a field of view of 24 degree.
Machemer Magnifying Irrigating Vitrectomy Lens (Plano/-45D)
This lens is designed to visualize the structures deep in the vitreous in phakic & pseudophakic eyes. The lens has a 36 degree field of view.
Paymen Wide field Irrigating Vitrectomy Lens
This lens is designed for wide angle viewing of phakic, fluid filled eyes during vitrectomy. The lens helps in visualization of the posterior and peripheral fundus in phakic and aphakic eyes. It is also useful in endolaser of peripheral fundus. |
 |
| |
Backflush Flute Needle with Silicon tip |
|
| |
This instrument incorporates a silicon backflush reservoir onto the conventional flute needle, which helps in safe backflushing of the incarcerated tissue during aspiration of intraocular fluids. This instrument comes in a wide range of tips for specialized applications. |
 |
| |
Silicon Tip Cannula |
|
| |
- Silicon tipped needle (straight / curved): 20 G stainless steel needle with a soft silicon tip for atruamatic removal of intraocular fluids.
- Silicon brush needle (straight/curved) : 20-G stainless steel needle with a soft silicon tip that is fenestrated to create a brush like quality. Useful for atraumatic brushing of the retinal surface with simultaneous aspiration. May be useful for repositioning of retinal folds or breaks.
|
 |
| |
Infusion Cannula (2.5mm, 4mm & 6mm) |
|
| |
This is an ultra thinwall cannula (20 G) with 45? beveled tip along with a flexible silicon tubing. It is designed to provide more effective infusion than a regular wall cannula. The flexible tubing is 25 cm (10 in.) long and attaches to an infusion source. Both ends of the infusion cannula are strongly secured with the silicon tubing thereby making it an ideal instrument for silicon oil injection.
Tips Sizes : 2.5mm, 4.0 mm & 6.0 mm |
|
| |
Intraocular Magnet |
|
| |
This rare earth intraocular magnet is especially designed for the atraumatic removal of magnetic foreign bodies. The user friendly design and titanium body of the instrument helps in precise control during the surgery. The tips are available in three diameters ? 1.20mm, 1.60mm & 2.20mm |
 |
| |
Detachment Forceps |
|
| |
- A multipurpose forceps for retinal detachment surgery which can be used as a
- Muscle hook to hook the recti muscles
- To pass the bridal suture under the recti muscles
- To pass the silicon band under the recti muscles
- As a single prong retractor
- As a double prong retractor
- To handle conjunctiva while closing the wound
|
 |
| |
Silicon oil Injector |
|
| |
This instrument is used for controlled injection of the silicon oil into the eye with minimal efforts. The syringe filled with silicon oil is loaded onto the injector. Slow rotation of the handle pushes the syringe piston forward injecting the silicon oil in the eye. |
 |
| |
20 D Aspheric Lens |
|
| |
Dummy Text
This probe is designed to overcome problems associated with the stubborn/sticky epinucleus. Such an epinucleus is difficult to aspirate through with an I/A probe and poses danger of PC rent when aspirated through the phaco probe. A 1.0mm port size of this probe with a blunt tip helps in safe aspiration of even the toughest of epinucleus very easily. A very handy instrument to avoid tricky situation in phacoemulsification.
Preset vacuum and flow rate settings same as for I/A procedure
Compatible with all phaco machine tubing
Autoclavable |
 |
| |
Aspheric Lens-78 D & 90 D |
|
| |
These apsheric fundus lenses have established slit lamp indirect ophthalmoscopy as a standard diagnostic procedure for comprehensive fundus examination. The unique aspheric designs provide a very clear, wide angle fundus viewing ideal for static and dynamic fundoscopy. |
 |